Quantum G6 / G7 Diagnostic tool
5. Fault Codes
5.2. Error code 20
The heater shows FAULT 20 error code. (Series G6)
Cause:
This means the heater cannot sense the room temperature correctly.
Remedy :
Is this a new installation & is the installer is still with the heater?
YES
Ask the installer to switch off the heater at the supply (or both supplies) and make sure the supplies are dead.
Ask them to remove the right hand & front cover so they can clearly see the Charge Controller PCB.
Ask them to check the room sensor cable is plugged into the PCB in the socket marked ROOM. See picture -
If the sensor plug was loose or not plugged in, hopefully pushing it back in will resolve the issue. Once covers are on and heater is powered up, the heater should work OK.
If FAULT 20 persists, raise an engineer visit - Take 03/82034/0 Charge Controller (includes room sensor in this part).
NO
Send engineer
Take 03/82034/0 Charge Controller (includes room sensor in this part).