Quantum G6 / G7 Diagnostic tool
8. Power Issues
.
Product Dead
Note this is VERY rare, especially “out of the box” as each heater is tested at the end of the factory line.
Cause :
• No peak supply present.
Remedy :
- Check both isolation switches on wall switched ON.
- Check fuse in wall switch is OK.
- Check all MCBs are switched ON.
- Check cable terminations in fuse spur and on heater terminal block.
Cause:
Peak & off-peak supplies swapped wrong way around by installer?
Remedy:
Symptoms will be display only works at night when off-peak supply energises. Swap peak & off-peak cables round the correct way.
Cause:
• Switch on wall faulty.
Remedy:
- Customer to replace
Replace switch from van stock / pick one up from wholesaler & fit as goodwill gesture. After all, customer may have been without heat for a while.
Cause:
• Screen accidentally unplugged from Charge Controller whilst installing.
Remedy:
- Installer to check UI cable is correctly connected to CC board.
Cause:
Fault with UI screen or Charge Controller.
Remedy:
Change UI & power on heater. If UI still dead, isolate mains. Check all connections to CC PCB. If suspected faulty, take photo of PCB then replace. PHOTO DATA BADGE FOR REPORT.